Unit 4, Berbax Industria, 41 Berkley Rd, Maitland, Cape Town, 7405
021 510 0139 info@3dceilings.co.za

Energylite

Glasswool: A range of commercial & industrial batts & blankets
Energylite is manufactured from non-combustible Glasswool bonded with an inert thermosetting resin to form a strong resilient product. Available in batts and blankets.
Energylite Application
Energylite
 
 
 
 

Key Benefits

Lifelong energy savings
Available in a variety of thicknesses and densities to suit the application
Safe application and use
Long product life
Exceptional acoustic and thermal properties

Technical Properties

Performance Code Value Unit Comment
Conductivity K 0,036 W/m.K 24 kg/m³
Conductivity K 0,032 W/m.K 47.5 kg/m³
Conductivity K 0,032 W/m.K 64 kg/m³
Conductivity K 0,032 W/m.K 80 kg/m³

Variants Details

default

SKU Thickness Width Length Thermal resistance NRC Value
10430 (47.5D Rolls) 50 1200 5000 1,56 0,95
10521 (24D Rolls) 75 1200 3000 2,08  
10607 (47.5D Batts) 25 600 1200 0,78  
10775 (47.5D Rolls) 40 1200 8000 1,25  
10804 (64D Batts) 25 600 1200 0,78  
10805 (64D Batts) 50 600 1200 1,56 1,00
10872 (24D Batts) 100 600 1200 2,78  
11336 (24D Batts) 75 600 1200 2,08  
11338 (47.5D Batts) 40 600 1200 1,25  
11339 (47.5D Batts) 50 600 1200 1,56 0,95
11342 (64D Batts) 40 600 1200 1,25  
11348 (24D Rolls) 25 1200 10000 0,69  
11351 (24D Rolls) 40 1200 8000 1,11  
11352 (24D Rolls) 50 1200 5000 1,39 0,90
11353 (47.5D Rolls) 25 1200 10000 0,78  
14600 (24D Batts) 25 600 1200 0,69  
14601 (24D Batts) 40 600 1200 1,11  
14602 (24D Batts) 50 600 1200 1,39 0,90
15662 (80D Batts) 25 600 1200 0,76  

Availability

Stock items (1 - 3 working days)
Standard items (3 - 7 working days)
Made to order items (7 - 15 working days)

FIRE PROPERTIES

  • All low binder Glasswool products are inherently non-combustible
  • Non-combustible - tested to SANS 10177 Part 5
  • Tested to ASTM E-84
    • Flame Spread Index: 10
    • Smoke Development Index: 5

 

APPLICATIONS

  • A range of batts and blankets for thermal and acoustic control in commercial buildings
  • An industrial thermal insulation for applications up to 450℃
  • Conservation and control of heat in boilers, tanks, ductwork, ovens, etc.
  • Acoustical correction in compressor houses and machine rooms

Certifications

ISO 9001 Springs
ISO 14001