Factoryboard is a rigid board manufactured from non-combustible Glasswool insulation. Available in 25, 40 or 50 mm thickness. It can be supplied with an ASTM E-84 tested reinforced foil or white metalised foil. Alternative facings are also available (white embossed vinyl or black non-woven glass tissue).


Key Benefits
Lifelong energy savings
Excellent thermal and acoustic properties
Maintenance free
Long product life - will not readily age
Significantly reduces heat loss/gain
Made to size to reduce wastage
Technical Properties
Performance | Code | Value | Unit | Comment |
---|---|---|---|---|
Conductivity | K | 0,032 | W/m.K | 80 kg/m³ |
Typical values and standard product dimensions
• Lengths can be tailor-made in metric units to the nearest 100 mm
• Maximum recommended lengths: 25 mm Board - 2.8 m, 40 & 50 mm Board - 3.2 m
• Lengths can be tailor-made in metric units to the nearest 100 mm
• Maximum recommended lengths: 25 mm Board - 2.8 m, 40 & 50 mm Board - 3.2 m
Variants Details
default
SKU | Thickness | Width | Length | Thermal resistance | NRC Value |
---|---|---|---|---|---|
10716 (Foil) | 25 | 1200 | 2400 | 0,78 | 0,65 |
10717 (Foil) | 40 | 1200 | 2400 | 1,25 | 0,75 |
11365 (WMF) | 25 | 1200 | 2400 | 0,78 | 0,65 |
11366 (WMF) | 40 | 1200 | 2400 | 1,25 | 0,75 |
14690 (WMF) | 50 | 1200 | 2400 | 1,56 | |
14691 (Foil) | 50 | 1200 | 2400 | 1,56 |
Availability
Standard items (3 - 7 working days)
Stock items (1 - 3 working days)
Made to order items (7 - 15 working days)
FIRE PROPERTIES
Foil:
Foil:
- Class 1 fire index rating - tested to SANS 10177 Part 3
- Class A1, s1, d0 according to EN 13823
- EUROCLASS A2 - EN 13501-1
- Tested to ASTM E-84
- Flame Spread Index: 10
- Smoke Development Index: 0
WMF:
- Tested to ASTM E-84
- Flame Spread Index: 20
- Smoke Development Index: 15
APPLICATIONS
- Multi-purpose wall cladding:
- Use 80 kg/m3 density
- Recommended to be installed in a grid system
- Over purlin roof insulation for new buildings or in a supporting grid system for existing buildings
- Use 80 kg/m3 density in horizontal applications
- Should not be installed in applications where the facing material is exposed to direct or indirect ultraviolet radiation
Related Documentation
Document | Category | Language | |
---|---|---|---|
![]() Factoryboard Data Sheet2015 / 02 / 15
|
Technical Documents Glasswool | ||
![]() Factoryboard Installation Methodology - Overperlin Review2015 / 02 / 15
|
Technical Documents Glasswool | ||
![]() Factoryboard Specification2015 / 02 / 15
|
Technical Documents Glasswool |